Products
Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Datasheet | Factory Lead Time | Published | Series | Part Status | Moisture Sensitivity Level (MSL) | Length | RoHS Status | Additional Feature | Reach Compliance Code | Impedance | Approval Agency | Resistance | Operating Temperature | Shielding | Rated Voltage | Insulation Material | Number of Conductors | Feature | Connector Support Type | Wire Gauge | Conductor Material | Jacket (Insulation) Material | Jacket Color | Jacket (Insulation) Diameter | Dielectric Material | Construction | Stranding | Wire and Cable Name | Usage | Cable Type | Cable Group | Shield Material | Conductor Strand | Shield Type | Shield Coverage | Dielectric Diameter | VoP, Velocity of Propagation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3092Z 0105000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
6 Weeks | ControlNet™ | Active | Not Applicable | 5000.0' 1524.00m | 75Ohms | -20°C~75°C | Quad Shield | 18 AWG | Steel, Copper Coated | Low Smoke Zero Halogen (LSZH) | Black | 0.300 (7.62mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 82 | ||||||||||||||||||||
9463 00310000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
6 Weeks | Blue Hose® | Active | Not Applicable | 10000' 3048.00m | RoHS Compliant | compliant | 78Ohm | CE; CEC; CUL; NEC; UL | 0.031Ohm | -40°C~80°C | YES | 300V | PE | 2 | Drain Wire, Oil Resistant, UV Resistant | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Orange | 0.238 (6.05mm) | Polyethylene (PE) | STRANDED | 7X28 | COMMUNICATION CABLE | Twinaxial | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 55% | 0.078 (1.98mm) | 66 | |||||||||
3093A 0105000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | ControlNet™ | Active | Not Applicable | 5000.0' 1524.00m | RoHS Compliant | 100Ohm | -20°C~150°C | Quad Shield | 18 AWG | Steel, Copper Coated | Polyvinylidene Fluoride (PVDF) | Black | 0.274 (6.96mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Coaxial - Plenum | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60%, 100%, 40% | 0.170 (4.32mm) | 82 | |||||||||||||||||||
81553 0061000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
15 Weeks | Active | Not Applicable | 1000.0' 304.80m | Non-RoHS Compliant | compliant | 77Ohm | -55°C~200°C | WIRE AND CABLE | 24 AWG | Copper Alloy, Silver Coated | Perfluoroalkoxy (PFA) | Blue | 0.129 (3.28mm) | Tetrafluoroethylene (TFE) | Twinaxial - Plenum | Copper Alloy, Silver Coated | 19 Strands / 36 AWG | Braid | 93% | 0.042 (1.07mm) | 70 | ||||||||||||||||||||
89907 E4X2500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
5 Weeks | 2012 | Active | Not Applicable | 2500.0' 762.00m | RoHS Compliant | compliant | 50Ohm | -20°C~150°C | WIRE AND CABLE | 20 AWG | Copper, Tinned | Polyvinylidene Fluoride (PVDF) | Gray | 0.160 (4.06mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Thinnet - Plenum | RG-58 | Aluminum; Copper, Tinned | 19 Strands / 32 AWG | Foil, Braid | 100%, 93% | 0.095 (2.41mm) | 80 | ||||||||||||||||||
83284 009100 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
23 Weeks | 2002 | Active | 1 (Unlimited) | 100.0' 30.48m | ROHS3 Compliant | STANDARDS: MIL-C-17, M17/113-RG316/U | 50Ohm | MIL | 0.276Ohm | -70°C~200°C | YES | 900V | TFE | 1 | WIRE AND CABLE | 26 AWG | Steel, Copper Covered, Silver Coated | Fluorinated Ethylene-Propylene (FEP) | White | 0.098 (2.48mm) | Tetrafluoroethylene (TFE) | STRANDED | 7X34 | COMMUNICATION CABLE | Coaxial | Copper, Silver Coated | 7 Strands / 34 AWG | Braid | 95% | 0.058 (1.47mm) | 69.5 | ||||||||||
83284 0091000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
11 Weeks | 2011 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | STANDARDS: MIL-C-17, M17/113-RG316/U | 50Ohm | MIL | 0.276Ohm | -70°C~200°C | YES | 900V | TFE | 1 | WIRE AND CABLE | 26 AWG | Steel, Copper Covered, Silver Coated | Fluorinated Ethylene-Propylene (FEP) | White | 0.098 (2.48mm) | Tetrafluoroethylene (TFE) | STRANDED | 7X34 | COMMUNICATION CABLE | Coaxial | Copper, Silver Coated | 7 Strands / 34 AWG | Braid | 95% | 0.058 (1.47mm) | 69.5 | ||||||||||
8216 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2011 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 50Ohm | -40°C~75°C | WIRE AND CABLE | 26 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.110 (2.79mm) | Polyethylene (PE) | Coaxial | RG-174 | Copper, Tinned | 7 Strands / 34 AWG | Braid | 90% | 0.060 (1.52mm) | 66 | |||||||||||||||||||
8216 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2007 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 50Ohm | -40°C~75°C | WIRE AND CABLE | 26 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.110 (2.79mm) | Polyethylene (PE) | Coaxial | RG-174 | Copper, Tinned | 7 Strands / 34 AWG | Braid | 90% | 0.060 (1.52mm) | 66 | |||||||||||||||||||
8240 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2011 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 52Ohm | -40°C~75°C | WIRE AND CABLE | 20 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.193 (4.90mm) | Polyethylene (PE) | Coaxial | RG-58A | Copper, Tinned | Solid | Braid | 95% | 0.116 (2.95mm) | 66 | ||||||||||||||||||
9239 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
8 Weeks | 2011 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 50Ohm | -40°C~60°C | WIRE AND CABLE | 26 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.101 (2.57mm) | Polyethylene (PE), Poly-Vinyl Chloride (PVC) | Coaxial | RG-174 | Copper, Tinned | 7 Strands / 34 AWG | Braid | 90% | 0.056 (1.42mm) | 62 | |||||||||||||||||||
7806A 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2001 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 50Ohm | -40°C~80°C | WIRE AND CABLE | 19 AWG | Copper, Bare | Polyethylene (PE) | Black | 0.195 (4.95mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | RG-58 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 90% | 0.110 (2.79mm) | 77 | ||||||||||||||||||
9463 J22100 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | 2009 | Blue Hose® | Active | Not Applicable | 100.0' 30.48m | ROHS3 Compliant | 78Ohm | CE; CEC; CUL; NEC; UL | 0.031Ohm | -40°C~80°C | YES | 300V | PE | 2 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Blue | 0.238 (6.05mm) | Polyethylene (PE) | STRANDED | 7X28 | COMMUNICATION CABLE | Twinaxial - Plenum | Aluminum; Copper, Tinned | 7 Strands / 33 AWG | Foil, Braid | 100%, 55% | 0.078 (1.98mm) | 66 | ||||||||||
543945 010U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 20 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.232 (5.89mm) | Foam Polyethylene (FPE) | CCTV | Coaxial | RG-59 | Copper, Bare | Solid | Braid | 93% | 0.145 (3.68mm) | 83 | |||||||||||||||||||
9259 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2001 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 22 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.241 (6.12mm) | Foam Polyethylene (FPE) | CCTV | Coaxial | RG-59 | Copper, Bare | 7 Strands / 30 AWG | Braid | 95% | 0.146 (3.71mm) | 78 | |||||||||||||||||
549945 009500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | 2012 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -30°C~80°C | WIRE AND CABLE | 20 AWG, 18 AWG (2) | Copper, Bare | Poly-Vinyl Chloride (PVC) | White | Foam High Density Polyethylene (FHDPE), Polypropylene (PP) | CCTV | Coaxial, Twisted Pair - Combo | RG-59 | Copper, Bare | Solid, 7 Strands / 26 AWG (2) | 0.059 (1.50mm), 0.145 (3.68mm) | 83 | ||||||||||||||||||||
8240 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2011 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 52Ohm | -40°C~75°C | WIRE AND CABLE | 20 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.193 (4.90mm) | Polyethylene (PE) | Coaxial | RG-58A | Copper, Tinned | Solid | Braid | 95% | 0.116 (2.95mm) | 66 | ||||||||||||||||||
9116 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | 2008 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.270 (6.86mm) | Foam Polyethylene (FPE) | CATV | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||||||||||||
8219 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2012 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 54Ohm | CE; CEC; CUL; NEC; UL | 0.029Ohm | -40°C~80°C | YES | 30V | FPE | 1 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Black | 0.193 (4.90mm) | Foam Polyethylene (FPE) | STRANDED | 19X32 | COMMUNICATION CABLE | Coaxial | RG-58A | Copper, Tinned | 19 Strands / 32 AWG | Braid | 95% | 0.114 (2.90mm) | 73 | ||||||||||
9239 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2011 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 50Ohm | -40°C~60°C | WIRE AND CABLE | 26 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.101 (2.57mm) | Polyethylene (PE), Poly-Vinyl Chloride (PVC) | Coaxial | RG-174 | Copper, Tinned | 7 Strands / 34 AWG | Braid | 90% | 0.056 (1.42mm) | 62 | |||||||||||||||||||
543945X 0091000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | |||||||||||||||||||||||||||||||||||||||
1523AN 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2018 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 14 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.400 (10.16mm) | Foam Polyethylene (FPE) | CATV | Coaxial | RG-11 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.280 (7.11mm) | 83 | |||||||||||||||||
1371P 003500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Orange | 0.160 (4.06mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Analog Video | Coaxial - Plenum | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 80 | |||||||||||||||||||
1371P 006500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Blue | 0.160 (4.06mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Analog Video | Coaxial - Plenum | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 80 | |||||||||||||||||||
1841AC 008500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2018 | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG (2) | Copper, Bare | Poly-Vinyl Chloride (PVC) | Gray | Foam Polyethylene (FPE) | Coaxial | RG-6, Dual | Aluminum | Solid (2) | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||||||||||||||
9058X 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | |||||||||||||||||||||||||||||||||||||||
9077 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2008 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG (2) | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | Foam Polyethylene (FPE) | CATV | Coaxial | RG-6, Dual | Aluminum | Solid (2) | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | ||||||||||||||||||
9058X 010U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | |||||||||||||||||||||||||||||||||||||||
1371P 008500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Gray | 0.160 (4.06mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Analog Video | Coaxial - Plenum | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 80 | |||||||||||||||||||
543945X010U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable |