Products
Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Datasheet | Factory Lead Time | Published | Series | Part Status | Moisture Sensitivity Level (MSL) | Length | RoHS Status | Additional Feature | Reach Compliance Code | Impedance | Approval Agency | Resistance | Operating Temperature | Shielding | Rated Voltage | Insulation Material | Number of Conductors | Connector Support Type | Wire Gauge | Conductor Material | Jacket (Insulation) Material | Jacket Color | Jacket (Insulation) Diameter | Dielectric Material | Construction | Stranding | Wire and Cable Name | Usage | Cable Type | Cable Group | Shield Material | Conductor Strand | Shield Type | Shield Coverage | Dielectric Diameter | VoP, Velocity of Propagation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1829P 877U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | 2018 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Low Smoke Poly-Vinyl Chloride (LSPVC) | Natural | 0.235 (5.97mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Coaxial - Plenum | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.170 (4.32mm) | 83 | |||||||||||||||||
9269 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 93Ohm | -40°C~80°C | WIRE AND CABLE | 22 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.239 (6.07mm) | Semi Solid Polyethylene (SSPE) | Coaxial | RG-62A | Copper, Bare | Solid | Braid | 95% | 0.146 (3.71mm) | 84 | ||||||||||||||||||
9252 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2015 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | ||||||||||||||||||||||||||||||||||
1369P 0031000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 18 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Orange | 0.231 (5.87mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Analog Video | Coaxial - Plenum | RG-6 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.168 (4.27mm) | 83 | |||||||||||||||||
1505F G7W1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | ||||||||||||||||||||||||||||||||||
1369P 0041000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 18 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Yellow | 0.231 (5.87mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Analog Video | Coaxial - Plenum | RG-6 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.168 (4.27mm) | 83 | |||||||||||||||||
8238 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | ||||||||||||||||||||||||||||||||||
9555 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 23 AWG (2) | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | Polyethylene (PE) | Coaxial | RG-59 | Copper, Bare | Solid (2) | Braid | 95% | 0.146 (3.71mm) | 66 | |||||||||||||||||||
8232 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||||||||||||
9778 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | ||||||||||||||||||||||||||||||||||||
9815 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
5 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 100Ohm | -55°C~80°C | WIRE AND CABLE | 20 AWG | Copper, Bare; Copper, Tinned | High Density Polyethylene (HDPE) | Black | 0.330 (8.38mm) | Polyethylene (PE) | Twinaxial | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 95% | 66 | |||||||||||||||||||||
DAS300P 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | ||||||||||||||||||||||||||||||||||||||
1306SB 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
8 Weeks | Active | Not Applicable | RoHS Compliant | compliant | ||||||||||||||||||||||||||||||||||||
1694F Z4B1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | RoHS Compliant | WIRE AND CABLE | ||||||||||||||||||||||||||||||||||||
9248 0101640 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | RoHS Compliant | WIRE AND CABLE | ||||||||||||||||||||||||||||||||||||
1395R B591000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | 75Ohm | -40°C~75°C | 25 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Black | 0.345 (8.76mm) | Foam High Density Polyethylene (FHDPE) | Analog Video | Coaxial - Riser | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 95% | 0.074 (1.88mm) | 80 | |||||||||||||||||||
7806A 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2003 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 50Ohm | -40°C~80°C | WIRE AND CABLE | 19 AWG | Copper, Bare | Polyethylene (PE) | Black | 0.195 (4.95mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | RG-58 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 90% | 0.110 (2.79mm) | 77 | |||||||||||||||||
9463 J22U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | 2008 | Blue Hose® | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 78Ohm | CE; CEC; CUL; NEC; UL | 0.031Ohm | -40°C~80°C | YES | 300V | PE | 2 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Blue | 0.238 (6.05mm) | Polyethylene (PE) | STRANDED | 7X28 | COMMUNICATION CABLE | Twinaxial - Plenum | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 55% | 0.078 (1.98mm) | 66 | |||||||||
8219 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2010 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 54Ohm | CE; CEC; CUL; NEC; UL | 0.029Ohm | -40°C~80°C | YES | 30V | FPE | 1 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Black | 0.193 (4.90mm) | Foam Polyethylene (FPE) | STRANDED | 19X32 | COMMUNICATION CABLE | Coaxial | RG-58A | Copper, Tinned | 19 Strands / 32 AWG | Braid | 95% | 0.114 (2.90mm) | 73 | |||||||||
1694A 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2011 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 18 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.274 (6.96mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | RG-6 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 95% | 0.180 (4.57mm) | 82 | |||||||||||||||||
9463 J221000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
2 Weeks | 2012 | Blue Hose® | Active | Not Applicable | 1000.0' 304.80m | ROHS3 Compliant | 78Ohm | CE; CEC; CUL; NEC; UL | 0.031Ohm | -40°C~80°C | YES | 300V | PE | 2 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Blue | 0.238 (6.05mm) | Polyethylene (PE) | STRANDED | 7X28 | COMMUNICATION CABLE | Twinaxial - Plenum | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 55% | 0.078 (1.98mm) | 66 | |||||||||
3092A 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | 2008 | ControlNet™ | Active | Not Applicable | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.298 (7.57mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Double Braid | 100%, 60%, 40% | 0.180 (4.57mm) | 82 | ||||||||||||||||
1189A 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | 2003 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.294 (7.47mm) | Foam Polyethylene (FPE) | CATV | Coaxial | Aluminum | Solid | Foil, Double Braid | 100%, 60%, 40% | 0.180 (4.57mm) | 83 | |||||||||||||||||
643948 877U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2012 | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -20°C~75°C | WIRE AND CABLE | 20 AWG | Copper, Bare | Low Smoke Poly-Vinyl Chloride (LSPVC) | Natural | 0.192 (4.88mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Coaxial - Plenum | RG-59 | Copper, Bare | Solid | Braid | 95% | 0.135 (3.43mm) | 84 | |||||||||||||||||
1505A 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2011 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 20 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.233 (5.92mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | RG-59 | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 95% | 0.145 (3.68mm) | 82 | |||||||||||||||||
84316 001100 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
11 Weeks | 2003 | Active | 1 (Unlimited) | 100.0' 30.48m | ROHS3 Compliant | 50Ohm | -70°C~200°C | WIRE AND CABLE | 26 AWG | Steel, Copper Covered, Silver Coated | Fluorinated Ethylene-Propylene (FEP) | Brown | 0.096 (2.44mm) | Tetrafluoroethylene (TFE) | Coaxial | Copper, Silver Coated | 7 Strands / 34 AWG | Braid | 95% | 0.058 (1.47mm) | 69.5 | |||||||||||||||||||
9221 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2012 | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | 75Ohm | -40°C~60°C | WIRE AND CABLE | 30 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Black | 0.097 (2.46mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | Copper, Tinned | 7 Strands / 38 AWG | Braid | 90% | 0.058 (1.47mm) | 78 | ||||||||||||||||||
8262 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 5 Weeks | Active | 1 (Unlimited) | 500.0' 152.40m | ROHS3 Compliant | STANDARD: MIL-C-17, RG58C/U | 50Ohm | CE; MIL; UL | 0.035Ohm | -40°C~85°C | YES | 1400V | 1 | WIRE AND CABLE | 20 AWG | Copper, Tinned | Non Contaminating Poly-Vinyl Chloride (PVC) | Black | 0.195 (4.95mm) | Polyethylene (PE) | STRANDED | 19X33 | COMMUNICATION CABLE | Coaxial | Copper, Tinned | 19 Strands / 33 AWG | Braid | 95% | 0.115 (2.92mm) | 66 | ||||||||||
1855A 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 2 Weeks | 2011 | Active | 1 (Unlimited) | 1000.0' 304.80m | ROHS3 Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.159 (4.04mm) | Foam High Density Polyethylene (FHDPE) | Coaxial | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 95% | 0.102 (2.59mm) | 82 | ||||||||||||||||||
9223 010100 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 7 Weeks | 2003 | Active | 1 (Unlimited) | 100.0' 30.48m | ROHS3 Compliant | 50Ohm | -40°C~80°C | WIRE AND CABLE | 22 AWG | Copper, Tinned | Poly-Vinyl Chloride (PVC) | Black | 0.195 (4.95mm) | Polyethylene (PE) | Coaxial | RG-58 | Aluminum; Copper, Tinned | 7 Strands / 30 AWG | Foil, Braid | 100%, 95% | 0.112 (2.84mm) | 56 |
Products