Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Datasheet Factory Lead Time Published Series Part Status Moisture Sensitivity Level (MSL) Length RoHS Status Additional Feature Reach Compliance Code Impedance Approval Agency Resistance Operating Temperature Shielding Rated Voltage Insulation Material Number of Conductors Connector Support Type Wire Gauge Conductor Material Jacket (Insulation) Material Jacket Color Jacket (Insulation) Diameter Dielectric Material Construction Stranding Wire and Cable Name Usage Cable Type Cable Group Shield Material Conductor Strand Shield Type Shield Coverage Dielectric Diameter VoP, Velocity of Propagation
1829P 877U1000 1829P 877U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -20°C~75°C WIRE AND CABLE 18 AWG Steel, Copper Coated Low Smoke Poly-Vinyl Chloride (LSPVC) Natural 0.235 (5.97mm) Foam Fluorinated Ethylene Propylene (FFEP) Coaxial - Plenum RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.170 (4.32mm) 83
9269 0101000 9269 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 93Ohm -40°C~80°C WIRE AND CABLE 22 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.239 (6.07mm) Semi Solid Polyethylene (SSPE) Coaxial RG-62A Copper, Bare Solid Braid 95% 0.146 (3.71mm) 84
9252 0101000 9252 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2015 Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
1369P 0031000 1369P 0031000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -20°C~75°C WIRE AND CABLE 18 AWG Copper, Bare Low Smoke Poly-Vinyl Chloride (LSPVC) Orange 0.231 (5.87mm) Foam Fluorinated Ethylene Propylene (FFEP) Analog Video Coaxial - Plenum RG-6 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.168 (4.27mm) 83
1505F G7W1000 1505F G7W1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks 2012 Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
1369P 0041000 1369P 0041000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -20°C~75°C WIRE AND CABLE 18 AWG Copper, Bare Low Smoke Poly-Vinyl Chloride (LSPVC) Yellow 0.231 (5.87mm) Foam Fluorinated Ethylene Propylene (FFEP) Analog Video Coaxial - Plenum RG-6 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.168 (4.27mm) 83
8238 010500 8238 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks 2012 Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
9555 010500 9555 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 23 AWG (2) Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black Polyethylene (PE) Coaxial RG-59 Copper, Bare Solid (2) Braid 95% 0.146 (3.71mm) 66
8232 010500 8232 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
9778 0101000 9778 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable RoHS Compliant
9815 010500 9815 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

5 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant 100Ohm -55°C~80°C WIRE AND CABLE 20 AWG Copper, Bare; Copper, Tinned High Density Polyethylene (HDPE) Black 0.330 (8.38mm) Polyethylene (PE) Twinaxial Aluminum; Copper, Tinned 7 Strands / 28 AWG Foil, Braid 100%, 95% 66
DAS300P 010500 DAS300P 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable
1306SB 010500 1306SB 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

8 Weeks Active Not Applicable RoHS Compliant compliant
1694F Z4B1000 1694F Z4B1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable RoHS Compliant WIRE AND CABLE
9248 0101640 9248 0101640 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable RoHS Compliant WIRE AND CABLE
1395R B591000 1395R B591000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -40°C~75°C 25 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.345 (8.76mm) Foam High Density Polyethylene (FHDPE) Analog Video Coaxial - Riser RG-59 Mini Aluminum; Copper, Tinned Solid Foil, Braid 100%, 95% 0.074 (1.88mm) 80
7806A 010500 7806A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2003 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 50Ohm -40°C~80°C WIRE AND CABLE 19 AWG Copper, Bare Polyethylene (PE) Black 0.195 (4.95mm) Foam High Density Polyethylene (FHDPE) Coaxial RG-58 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 90% 0.110 (2.79mm) 77
9463 J22U500 9463 J22U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

10 Weeks 2008 Blue Hose® Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 78Ohm CE; CEC; CUL; NEC; UL 0.031Ohm -40°C~80°C YES 300V PE 2 WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Blue 0.238 (6.05mm) Polyethylene (PE) STRANDED 7X28 COMMUNICATION CABLE Twinaxial - Plenum Aluminum; Copper, Tinned 7 Strands / 28 AWG Foil, Braid 100%, 55% 0.078 (1.98mm) 66
8219 010500 8219 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks 2010 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 54Ohm CE; CEC; CUL; NEC; UL 0.029Ohm -40°C~80°C YES 30V FPE 1 WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.193 (4.90mm) Foam Polyethylene (FPE) STRANDED 19X32 COMMUNICATION CABLE Coaxial RG-58A Copper, Tinned 19 Strands / 32 AWG Braid 95% 0.114 (2.90mm) 73
1694A 0101000 1694A 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2011 Active 1 (Unlimited) 1000.0' 304.80m ROHS3 Compliant 75Ohm -30°C~75°C WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.274 (6.96mm) Foam High Density Polyethylene (FHDPE) Coaxial RG-6 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 95% 0.180 (4.57mm) 82
9463 J221000 9463 J221000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks 2012 Blue Hose® Active Not Applicable 1000.0' 304.80m ROHS3 Compliant 78Ohm CE; CEC; CUL; NEC; UL 0.031Ohm -40°C~80°C YES 300V PE 2 WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Blue 0.238 (6.05mm) Polyethylene (PE) STRANDED 7X28 COMMUNICATION CABLE Twinaxial - Plenum Aluminum; Copper, Tinned 7 Strands / 28 AWG Foil, Braid 100%, 55% 0.078 (1.98mm) 66
3092A 010500 3092A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks 2008 ControlNet™ Active Not Applicable 500.0' 152.40m ROHS3 Compliant 75Ohm -30°C~75°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.298 (7.57mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Double Braid 100%, 60%, 40% 0.180 (4.57mm) 82
1189A 0101000 1189A 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks 2003 Active 1 (Unlimited) 1000.0' 304.80m ROHS3 Compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.294 (7.47mm) Foam Polyethylene (FPE) CATV Coaxial Aluminum Solid Foil, Double Braid 100%, 60%, 40% 0.180 (4.57mm) 83
643948 877U500 643948 877U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2012 Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -20°C~75°C WIRE AND CABLE 20 AWG Copper, Bare Low Smoke Poly-Vinyl Chloride (LSPVC) Natural 0.192 (4.88mm) Foam Fluorinated Ethylene Propylene (FFEP) Coaxial - Plenum RG-59 Copper, Bare Solid Braid 95% 0.135 (3.43mm) 84
1505A 010500 1505A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2011 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 75Ohm -30°C~75°C WIRE AND CABLE 20 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.233 (5.92mm) Foam High Density Polyethylene (FHDPE) Coaxial RG-59 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 95% 0.145 (3.68mm) 82
84316 001100 84316 001100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

11 Weeks 2003 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 50Ohm -70°C~200°C WIRE AND CABLE 26 AWG Steel, Copper Covered, Silver Coated Fluorinated Ethylene-Propylene (FEP) Brown 0.096 (2.44mm) Tetrafluoroethylene (TFE) Coaxial Copper, Silver Coated 7 Strands / 34 AWG Braid 95% 0.058 (1.47mm) 69.5
9221 010500 9221 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2012 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 75Ohm -40°C~60°C WIRE AND CABLE 30 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.097 (2.46mm) Foam High Density Polyethylene (FHDPE) Coaxial Copper, Tinned 7 Strands / 38 AWG Braid 90% 0.058 (1.47mm) 78
8262 010500 8262 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 5 Weeks Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant STANDARD: MIL-C-17, RG58C/U 50Ohm CE; MIL; UL 0.035Ohm -40°C~85°C YES 1400V 1 WIRE AND CABLE 20 AWG Copper, Tinned Non Contaminating Poly-Vinyl Chloride (PVC) Black 0.195 (4.95mm) Polyethylene (PE) STRANDED 19X33 COMMUNICATION CABLE Coaxial Copper, Tinned 19 Strands / 33 AWG Braid 95% 0.115 (2.92mm) 66
1855A 0101000 1855A 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2011 Active 1 (Unlimited) 1000.0' 304.80m ROHS3 Compliant 75Ohm -30°C~75°C WIRE AND CABLE 23 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.159 (4.04mm) Foam High Density Polyethylene (FHDPE) Coaxial Aluminum; Copper, Tinned Solid Foil, Braid 100%, 95% 0.102 (2.59mm) 82
9223 010100 9223 010100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 7 Weeks 2003 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 50Ohm -40°C~80°C WIRE AND CABLE 22 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.195 (4.95mm) Polyethylene (PE) Coaxial RG-58 Aluminum; Copper, Tinned 7 Strands / 30 AWG Foil, Braid 100%, 95% 0.112 (2.84mm) 56