All Products

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Datasheet Factory Lead Time Published Series Part Status Moisture Sensitivity Level (MSL) Diameter Length RoHS Status Reach Compliance Code Impedance Approval Agency Resistance Operating Temperature Operating Temperature (Max) Operating Temperature (Min) Shielding Rated Voltage Application Insulation Material Number of Conductors Feature Connector Support Type Wire Gauge Conductor Material Jacket (Insulation) Material Jacket Color Jacket (Insulation) Diameter Dielectric Material Construction Wire and Cable Name Usage Cable Type Cable Group Shield Material Conductor Strand Shield Type Shield Coverage Dielectric Diameter VoP, Velocity of Propagation
179DTNH 0021000 179DTNH 0021000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

15 Weeks Active Not Applicable 2.69mm RoHS Compliant compliant CEC; CUL; NEC; UL 0.231Ohm 75°C -20°C YES 300V BROADCAST MOBILE TRUCKS, DIGITAL VIDEO, PRECISION VIDEO FHDPE 1 WIRE AND CABLE 28.5 AWG BARE COPPER POLYVINYL CHLORIDE SOLID COMMUNICATION CABLE
9907 E4X1000 9907 E4X1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 50Ohm -40°C~80°C WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Gray 0.185 (4.70mm) Foam High Density Polyethylene (FHDPE) Thinnet RG-58 Aluminum; Copper, Tinned 19 Strands / 32 AWG Foil, Braid 100%, 93% 0.102 (2.59mm) 80
25339Q5 0001000 25339Q5 0001000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

5 Weeks Active Not Applicable 1000.0' 304.80m 75Ohm -40°C~80°C Quad Shield 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) 0.501 (12.73mm) Foam Polyethylene (FPE) CATV, MATV Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60%, 100%, 40% 0.180 (4.57mm) 83
6788AV 009250 6788AV 009250 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2017 Active Not Applicable 250.0' 76.20m RoHS Compliant 75Ohm 0°C~75°C Drain Wire 25 AWG (6), 22 AWG (4) Copper, Tinned Low Smoke Poly-Vinyl Chloride (LSPVC) White 0.426 (10.82mm) Foam Perflouoroalkoxy (FPFA), Low Smoke Poly-Vinyl Chloride (LSPVC) Analog Video Coaxial, Twisted Pair - Combo - Plenum RG-59 Mini Aluminum; Copper, Tinned Solid (6), 7 Strands / 30 AWG (4) Foil, Braid 100%, 95% 0.074 (1.88mm) 80
7500A G7X1000 7500A G7X1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

14 Weeks MachFlex™ Active Not Applicable 1000.0' 304.80m compliant 75Ohm -40°C~80°C WIRE AND CABLE 30 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Blue 0.110 (2.79mm) Foam Polyethylene (FPE) Datacom Coaxial Copper, Tinned 7 Strands / 38 AWG Braid 95% 0.056 (1.42mm) 78
734A12 008500 734A12 008500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
88232 010500 88232 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks 2012 Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
DA7732A 8771000 DA7732A 8771000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable
7732A 0101200 7732A 0101200 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks Active Not Applicable RoHS Compliant WIRE AND CABLE
7732A 0061000 7732A 0061000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks Active Not Applicable RoHS Compliant WIRE AND CABLE
DA7732A 0104000 DA7732A 0104000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable
735A16 0081000 735A16 0081000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable
9118 0101000 9118 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2008 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1840A 010500 1840A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable 500.0' 152.40m RoHS Compliant compliant 75Ohm -40°C~80°C Used in Aerial Applications WIRE AND CABLE 18 AWG (2) Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black Foam Polyethylene (FPE) Coaxial RG-6, Dual Aluminum Solid (2) Foil, Braid 100%, 60% 0.180 (4.57mm) 83
5339Q5 009U500 5339Q5 009U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2011 Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -40°C~80°C Quad Shield WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) White 0.298 (7.57mm) Foam Polyethylene (FPE) CATV, MATV Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60%, 100%, 40% 0.180 (4.57mm) 83
1370R 010500 1370R 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 20 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.202 (5.13mm) Foam High Density Polyethylene (FHDPE) Analog Video Coaxial - Riser RG-59 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.136 (3.45mm) 84
1829AC 0091000 1829AC 0091000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) White 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
573945 006U1000 573945 006U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m 75Ohm -30°C~75°C 25 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Blue 0.146 (3.71mm) Foam Polyethylene (FPE) CCTV Coaxial RG-59 Mini Copper, Bare Solid Braid 94% 0.085 (2.16mm) 80
1829BC 0101000 1829BC 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -55°C~80°C WIRE AND CABLE 18 AWG Copper, Bare Polyethylene (PE) Black 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
573945 0021000 573945 0021000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2006 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 25 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Red 0.146 (3.71mm) Foam Polyethylene (FPE) CCTV Coaxial RG-59 Mini Copper, Bare Solid Braid 94% 0.085 (2.16mm) 80
573945 0061000 573945 0061000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2006 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 25 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Blue 0.146 (3.71mm) Foam Polyethylene (FPE) CCTV Coaxial RG-59 Mini Copper, Bare Solid Braid 94% 0.085 (2.16mm) 80
9100 0101000 9100 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -40°C~80°C WIRE AND CABLE 20 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.237 (6.02mm) Foam Polyethylene (FPE) Coaxial RG-59 Aluminum Solid Foil, Braid 100%, 40% 0.144 (3.66mm) 83
1614B 0031000 1614B 0031000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -55°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Polyethylene (PE) Orange 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1840AC 008500 1840AC 008500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 500.0' 152.40m RoHS Compliant compliant 75Ohm -40°C~80°C Used in Aerial Applications WIRE AND CABLE 18 AWG (2) Copper, Bare Poly-Vinyl Chloride (PVC) Gray Foam Polyethylene (FPE) Coaxial RG-6, Dual Aluminum Solid (2) Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1613A 010A1000 1613A 010A1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1613A Q5HU1000 1613A Q5HU1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) White 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1829AC 010U1000 1829AC 010U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2012 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1614B 0101000 1614B 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant 75Ohm -55°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Polyethylene (PE) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
9104 0101000 9104 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2008 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 20 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.237 (6.02mm) Foam High Density Polyethylene (FHDPE) Coaxial RG-59 Aluminum Solid Foil, Braid 100%, 65% 0.144 (3.66mm) 83
9275 0101000 9275 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 20 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.237 (6.02mm) Foam Polyethylene (FPE) Coaxial RG-59 Aluminum Solid Foil, Braid 100%, 40% 0.144 (3.66mm) 83