Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Datasheet | Factory Lead Time | Published | Series | Part Status | Moisture Sensitivity Level (MSL) | Length | RoHS Status | Reach Compliance Code | Impedance | Operating Temperature | Feature | Connector Support Type | Wire Gauge | Conductor Material | Jacket (Insulation) Material | Jacket Color | Jacket (Insulation) Diameter | Dielectric Material | Usage | Cable Type | Cable Group | Shield Material | Conductor Strand | Shield Type | Shield Coverage | Dielectric Diameter | VoP, Velocity of Propagation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1672A TIN1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | 2012 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -70°C~200°C | WIRE AND CABLE | 29 AWG | Steel, Copper Covered, Silver Coated | 0.087 (2.21mm) | Tetrafluoroethylene (TFE) | Coaxial | Copper, Bare; Tin | Solid | Foil, Braid | 100% | 0.062 (1.57mm) | ||||||||||||
89272 0061000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2012 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 78Ohm | -70°C~200°C | WIRE AND CABLE | 20 AWG | Copper, Tinned | Fluorinated Ethylene-Propylene (FEP) | Blue | 0.198 (5.03mm) | Fluorinated Ethylene Propylene (FEP) | Twinaxial - Plenum | Copper, Tinned | 7 Strands / 28 AWG | Braid | 93% | 0.074 (1.88mm) | 69.5 | |||||||||
89207 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2012 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 100Ohm | -70°C~200°C | WIRE AND CABLE | 20 AWG | Copper, Bare; Copper, Tinned | Fluorinated Ethylene-Propylene (FEP) | Black | 0.259 (6.58mm) | Fluorinated Ethylene Propylene (FEP) | Twinaxial - Plenum | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 85% | 0.072 (1.83mm) | 69.5 | |||||||||
7787A B591000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | ||||||||||||||||||||||||||
9273 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
6 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||
9228 0105000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 5000.0' 1524.00m | RoHS Compliant | compliant | 93Ohm | -55°C~80°C | WIRE AND CABLE | 22 AWG | Steel, Copper Coated | High Density Polyethylene (HDPE) | Black | 0.242 (6.15mm) | Semi Solid Polyethylene (SSPE) | Coaxial | RG-62A | Copper, Bare | Solid | Braid | 95% | 0.146 (3.71mm) | 84 | |||||||||
7792A B59500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2009 | Active | Not Applicable | RoHS Compliant | WIRE AND CABLE | ||||||||||||||||||||||||||
1671J 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||
9250 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
5 Weeks | 2012 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 95Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG (2) | Copper, Bare | Non Contaminating Poly-Vinyl Chloride (PVC) | Black | 0.416 (10.57mm) | Polyethylene (PE) | Twinaxial | RG-22B | Copper, Tinned | 7 Strands / 26 AWG (2) | Double Braid | 95% | 66 | |||||||||
1674A TIN1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||
3092F 0105000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
10 Weeks | ControlNet™ | Active | Not Applicable | 5000.0' 1524.00m | RoHS Compliant | 100Ohm | -40°C~75°C | Quad Shield | 20 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.303 (7.70mm) | Foam Polyethylene (FPE) | Coaxial - Riser | RG-6 | Aluminum | 105 Strands / 40 AWG | Foil, Braid | 100%, 60%, 100%, 40% | 0.183 (4.65mm) | 79 | |||||||||
89463 0062500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Blue Hose® | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | compliant | 120Ohm | -70°C~200°C | Drain Wire | 20 AWG | Copper, Tinned | Fluorinated Ethylene-Propylene (FEP) | Blue | 0.203 (5.16mm) | Fluorinated Ethylene Propylene (FEP) | Twinaxial - Plenum | Aluminum; Copper, Tinned | 7 Strands / 28 AWG | Foil, Braid | 100%, 76% | 0.073 (1.85mm) | 69 | |||||||||
1694S6 0001000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||
9913F7 B591000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2012 | Active | Not Applicable | RoHS Compliant | compliant | WIRE AND CABLE | |||||||||||||||||||||||||
89182 0105000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
4 Weeks | Active | Not Applicable | 5000.0' 1524.00m | 150Ohm | -70°C~200°C | Drain Wire | 22 AWG | Copper, Tinned | Fluorinated Ethylene-Propylene (FEP) | Black | 0.307 (7.80mm) | Foam Fluorinated Ethylene Propylene (FFEP) | Twinaxial - Plenum | Aluminum | 19 Strands / 34 AWG | Foil | 100% | 78 | |||||||||||||
1371R 007500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Violet | 0.160 (4.06mm) | Foam High Density Polyethylene (FHDPE) | Analog Video | Coaxial - Riser | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 82 | |||||||||
1371R 006500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Blue | 0.160 (4.06mm) | Foam High Density Polyethylene (FHDPE) | Analog Video | Coaxial - Riser | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 82 | |||||||||
1371R 002500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Red | 0.160 (4.06mm) | Foam High Density Polyethylene (FHDPE) | Analog Video | Coaxial - Riser | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 82 | |||||||||
1829A 008U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | 2018 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Gray | 0.270 (6.86mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||
1371R N3U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -30°C~75°C | WIRE AND CABLE | 23 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Green | 0.160 (4.06mm) | Foam High Density Polyethylene (FHDPE) | Analog Video | Coaxial - Riser | RG-59 Mini | Aluminum; Copper, Tinned | Solid | Foil, Braid | 100%, 85% | 0.102 (2.59mm) | 82 | |||||||||
9110 009U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 20 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | White | 0.242 (6.15mm) | Foam Polyethylene (FPE) | Coaxial | RG-59 | Aluminum | Solid | Foil, Braid | 100%, 67% | 0.144 (3.66mm) | 83 | ||||||||
P6ET77VVWBFC | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
6 Weeks | Active | Not Applicable | |||||||||||||||||||||||||||||
1829A 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | 2013 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.270 (6.86mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||
7915A 010U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2011 | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.275 (6.99mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 77% | 0.180 (4.57mm) | 83 | ||||||||
1829A 0081000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | 2013 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Gray | 0.270 (6.86mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||
1613AT 0101000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.278 (7.06mm) | Foam Polyethylene (FPE) | Coaxial | Aluminum | Solid | Foil, Braid | 100%, 77% | 0.180 (4.57mm) | 83 | |||||||||
5339B5 009500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 3 Weeks | Active | Not Applicable | 500.0' 152.40m | 75Ohm | -40°C~80°C | 18 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | White | 0.266 (6.76mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 | |||||||||||
1189A 010U500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | 2012 | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | 75Ohm | -40°C~80°C | Quad Shield | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | Black | 0.294 (7.47mm) | Foam Polyethylene (FPE) | CATV | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60%, 100%, 40% | 0.180 (4.57mm) | 83 | ||||||
7915A 010500 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
3 Weeks | 2013 | Active | Not Applicable | 500.0' 152.40m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Copper, Bare | Poly-Vinyl Chloride (PVC) | Black | 0.275 (6.99mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 77% | 0.180 (4.57mm) | 83 | ||||||||
1829A 009U1000 | Belden Inc. | $0.00 |
Min: 1 Mult: 1 |
download | 4 Weeks | 2013 | Active | Not Applicable | 1000.0' 304.80m | RoHS Compliant | compliant | 75Ohm | -40°C~80°C | WIRE AND CABLE | 18 AWG | Steel, Copper Coated | Poly-Vinyl Chloride (PVC) | White | 0.270 (6.86mm) | Foam Polyethylene (FPE) | Coaxial | RG-6 | Aluminum | Solid | Foil, Braid | 100%, 60% | 0.180 (4.57mm) | 83 |
Products