All Products

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Datasheet Factory Lead Time Published Part Status Moisture Sensitivity Level (MSL) Length RoHS Status Additional Feature Reach Compliance Code Impedance Approval Agency Resistance Operating Temperature Shielding Rated Voltage Insulation Material Number of Conductors Feature Connector Support Type Wire Gauge Conductor Material Jacket (Insulation) Material Jacket Color Jacket (Insulation) Diameter Dielectric Material Construction Stranding Wire and Cable Name Usage Cable Type Cable Group Shield Material Conductor Strand Shield Type Shield Coverage Dielectric Diameter VoP, Velocity of Propagation
1829A 008U1000 1829A 008U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Gray 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1371R N3U500 1371R N3U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 23 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Green 0.160 (4.06mm) Foam High Density Polyethylene (FHDPE) Analog Video Coaxial - Riser RG-59 Mini Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.102 (2.59mm) 82
9110 009U1000 9110 009U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 20 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) White 0.242 (6.15mm) Foam Polyethylene (FPE) Coaxial RG-59 Aluminum Solid Foil, Braid 100%, 67% 0.144 (3.66mm) 83
P6ET77VVWBFC P6ET77VVWBFC Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

6 Weeks Active Not Applicable
1829A 0101000 1829A 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2013 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
7915A 010U500 7915A 010U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks 2011 Active Not Applicable 500.0' 152.40m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1829A 0081000 1829A 0081000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2013 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Gray 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1613AT 0101000 1613AT 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.278 (7.06mm) Foam Polyethylene (FPE) Coaxial Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
5339B5 009500 5339B5 009500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 3 Weeks Active Not Applicable 500.0' 152.40m 75Ohm -40°C~80°C 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) White 0.266 (6.76mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1189A 010U500 1189A 010U500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2012 Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -40°C~80°C Quad Shield WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.294 (7.47mm) Foam Polyethylene (FPE) CATV Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60%, 100%, 40% 0.180 (4.57mm) 83
7915A 010500 7915A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks 2013 Active Not Applicable 500.0' 152.40m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1829A 009U1000 1829A 009U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks 2013 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) White 0.270 (6.86mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1370R 002500 1370R 002500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 20 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Red 0.202 (5.13mm) Foam High Density Polyethylene (FHDPE) Analog Video Coaxial - Riser RG-59 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.136 (3.45mm) 84
1613AT 010U1000 1613AT 010U1000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m 75Ohm -40°C~80°C 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.278 (7.06mm) Foam Polyethylene (FPE) Coaxial Aluminum Solid Foil, Braid 100%, 77% 0.180 (4.57mm) 83
1370R 004500 1370R 004500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

3 Weeks Active Not Applicable 500.0' 152.40m RoHS Compliant 75Ohm -30°C~75°C WIRE AND CABLE 20 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Yellow 0.202 (5.13mm) Foam High Density Polyethylene (FHDPE) Analog Video Coaxial - Riser RG-59 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 85% 0.136 (3.45mm) 84
9239 010100 9239 010100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

8 Weeks 2011 Active Not Applicable RoHS Compliant compliant WIRE AND CABLE
9118 0081000 9118 0081000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Gray 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1837A 0101000 1837A 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -55°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Polyethylene (PE) Black 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1258AM 0101000 1258AM 0101000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 4 Weeks Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -40°C~80°C Used in Aerial Applications WIRE AND CABLE 18 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black Foam Polyethylene (FPE) CATV Coaxial Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
1837A 0031000 1837A 0031000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

4 Weeks 2018 Active Not Applicable 1000.0' 304.80m RoHS Compliant compliant 75Ohm -55°C~80°C WIRE AND CABLE 18 AWG Steel, Copper Coated Polyethylene (PE) Orange 0.275 (6.99mm) Foam Polyethylene (FPE) Coaxial RG-6 Aluminum Solid Foil, Braid 100%, 60% 0.180 (4.57mm) 83
9272 006100 9272 006100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 10 Weeks 2011 Active Not Applicable 100.0' 30.48m ROHS3 Compliant 78Ohm -20°C~60°C WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Blue 0.244 (6.20mm) Polyethylene (PE) Twinaxial Copper, Tinned 7 Strands / 28 AWG Braid 93% 66
8216 010100 8216 010100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks 2007 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 50Ohm -40°C~75°C WIRE AND CABLE 26 AWG Steel, Copper Coated Poly-Vinyl Chloride (PVC) Black 0.110 (2.79mm) Polyethylene (PE) Coaxial RG-174 Copper, Tinned 7 Strands / 34 AWG Braid 90% 0.060 (1.52mm) 66
9222 004500 9222 004500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2001 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 50Ohm -40°C~75°C 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Yellow 0.241 (6.12mm) Polyethylene (PE) Coaxial RG-58A Copper, Tinned 7 Strands / 28 AWG Braid 95% 0.120 (3.05mm) 66
1855A 010500 1855A 010500 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2011 Active 1 (Unlimited) 500.0' 152.40m ROHS3 Compliant 75Ohm -30°C~75°C WIRE AND CABLE 23 AWG Copper, Bare Poly-Vinyl Chloride (PVC) Black 0.159 (4.04mm) Foam High Density Polyethylene (FHDPE) Coaxial RG-59 Aluminum; Copper, Tinned Solid Foil, Braid 100%, 95% 0.102 (2.59mm) 82
83265 009100 83265 009100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2012 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant STANDARD: MIL-C-17, M17/93-RG178 50Ohm UL 0.801Ohm -70°C~200°C YES TFE 1 WIRE AND CABLE 30 AWG Steel, Copper Covered, Silver Coated Fluorinated Ethylene-Propylene (FEP) White 0.071 (1.80mm) Tetrafluoroethylene (TFE) STRANDED 7X38 COMMUNICATION CABLE Coaxial Copper, Silver Coated 7 Strands / 38 AWG Braid 95% 0.033 (0.84mm) 69.5
8259 010100 8259 010100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2011 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 50Ohm -40°C~75°C WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.193 (4.90mm) Polyethylene (PE) Coaxial RG-58A Copper, Tinned 19 Strands / 33 AWG Braid 95% 0.116 (2.95mm) 66
83264 001100 83264 001100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

2 Weeks 2012 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 75Ohm -70°C~200°C WIRE AND CABLE 30 AWG Steel, Copper Covered, Silver Coated Fluorinated Ethylene-Propylene (FEP) Brown 0.100 (2.54mm) Tetrafluoroethylene (TFE) Coaxial Copper, Silver Coated 7 Strands / 38 AWG Braid 95% 0.062 (1.57mm) 69.5
9222 004100 9222 004100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 2 Weeks 2005 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 50Ohm -40°C~75°C YES 1400V PE 1 WIRE AND CABLE 20 AWG Copper, Tinned Poly-Vinyl Chloride (PVC) Yellow 0.241 (6.12mm) Polyethylene (PE) STRANDED 7X28 COMMUNICATION CABLE Coaxial RG-58A Copper, Tinned 7 Strands / 28 AWG Braid 95% 0.120 (3.05mm) 66
83265 0091000 83265 0091000 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 23 Weeks 2012 Active 1 (Unlimited) 1000.0' 304.80m ROHS3 Compliant STANDARD: MIL-C-17, M17/93-RG178 50Ohm UL 0.801Ohm -70°C~200°C YES TFE 1 WIRE AND CABLE 30 AWG Steel, Copper Covered, Silver Coated Fluorinated Ethylene-Propylene (FEP) White 0.071 (1.80mm) Tetrafluoroethylene (TFE) STRANDED 7X38 COMMUNICATION CABLE Coaxial Copper, Silver Coated 7 Strands / 38 AWG Braid 95% 0.033 (0.84mm) 69.5
9207 010100 9207 010100 Belden Inc. $0.00
RFQ

Min: 1

Mult: 1

download 10 Weeks 2011 Active 1 (Unlimited) 100.0' 30.48m ROHS3 Compliant 100Ohm -30°C~75°C WIRE AND CABLE 20 AWG (2) Copper, Bare; Copper, Tinned Poly-Vinyl Chloride (PVC) Black 0.330 (8.38mm) Polyethylene (PE) Twinaxial Aluminum; Copper, Tinned 7 Strands / 28 AWG (2) Foil, Braid 100%, 85% 0.236 (5.99mm) 66