78M6610+LMU/B01T

78M6610+LMU/B01T datasheet pdf and PMIC - Energy Metering product details from Maxim Integrated stock available at Utmel


  • Manufacturer: Maxim Integrated
  • Origchip NO: 503-78M6610+LMU/B01T
  • Package: 24-WFQFN Exposed Pad
  • Datasheet: PDF
  • Stock: 286
  • Description: 78M6610+LMU/B01T datasheet pdf and PMIC - Energy Metering product details from Maxim Integrated stock available at Utmel(Kg)

Purchase & Inquiry

Transport

Purchase

You may place an order without registering to Utmel.
We strongly suggest you sign in before purchasing as you can track your order in real time.

Means of Payment

For your convenience, we accept multiple payment methods in USD, including PayPal, Credit Card, and wire transfer.

RFQ (Request for Quotations)

It is recommended to request for quotations to get the latest prices and inventories about the part.
Our sales will reply to your request by email within 24 hours.

IMPORTANT NOTICE

1. You'll receive an order information email in your inbox. (Please remember to check the spam folder if you didn't hear from us).
2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.

Shipping Cost

Shipping starts at $40, but some countries will exceed $40. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)
The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and country.

Shipping Method

Currently, our products are shipped through DHL, FedEx, SF, and UPS.

Delivery Time

Once the goods are shipped, estimated delivery time depends on the shipping methods you chose:

FedEx International, 5-7 business days.

The following are some common countries' logistic time.
transport

Details

Tags

Parameters
Factory Lead Time 4 Weeks
Mounting Type Surface Mount
Package / Case 24-WFQFN Exposed Pad
Surface Mount YES
Number of Pins 24
Operating Temperature -40°C~85°C
Packaging Tape & Reel (TR)
Published 2013
Part Status Discontinued
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Number of Terminations 24
ECCN Code EAR99
Technology CMOS
Voltage - Supply 3V~3.6V
Terminal Position QUAD
Terminal Form NO LEAD
Peak Reflow Temperature (Cel) NOT SPECIFIED
Supply Voltage 3.3V
Terminal Pitch 0.5mm
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Base Part Number 78M6610
Pin Count 24
Operating Supply Voltage 3.3V
Interface I2C, SPI, UART
Memory Size 8kB
RAM Size 1.5kB
Memory Type FLASH
uPs/uCs/Peripheral ICs Type MICROPROCESSOR CIRCUIT
Current - Supply 8.1mA
Data Bus Width 24b
Number of Timers/Counters 1
Max Frequency 20MHz
Input Impedance 30kOhm~90kOhm
Meter Type Single Phase
Voltage - I/O Low 0.8V
Voltage - I/O High 2V
Height Seated (Max) 0.8mm
Length 4mm
RoHS Status ROHS3 Compliant
Lead Free Lead Free

78M6610+LMU/B01T Overview


In Tape & Reel (TR) package. Packet 24-WFQFN Exposed Pad. A Single Phase meter can be used with it as well. The following version of Surface Mount is available. As a result of -40°C~85°C, a higher operational temperature is reached. 3V~3.6V power supply is used to power it. If you are looking for parts similar to this one, search 78M6610. In its low-level I/O ports, this PMIC has a voltage of 0.8V. When using this device for high-level I/Os, the voltage presented by it is 2V. A 24 termination is included in the part. The normal voltage required for the part is 3.3V. The 24 pins are joined together. Logic gates can be applied to this 24 solution. The device is a 8.1mA. 3.3V can be used to supply this device. This device can work at a frequency up to 20MHz. As part of this PMIC, the memory size 8kB is included. The PMIC uses FLASH memory.

78M6610+LMU/B01T Features


Single Phase meter.
Operating maximum frequency: 20MHz.
8kB adequate size for target applications.
FLASH memory.

78M6610+LMU/B01T Applications


There are a lot of Maxim Integrated 78M6610+LMU/B01T Energy Metering ICs applications.

  • Subsystem Power Measurement
  • Poly-phase energy meters of class 0.5S and class 1
  • Intelligent Power Distribution Units
  • Central office equipment
  • Industrial Equipment
  • General Purpose Energy Measurement
  • Real-Time Measurement of Input Power for AC/DC Supplies
  • Power monitoring/power budgeting
  • Power Monitoring for Home Automation